Looking for a reliable and high-quality medical elbow high voltage cable? Look no further! Our factory produces top-notch products that meet industry standards. Order yours today.
High voltage cable (75KV/90KV) - introduction of elbow joint
Usage scenario
Company Strength
Original manufacturer of x- ray machine accessories hand switch and foot switch for more than 16 years. √ Customers could find all kinds of x-ray machine parts here. √ Offer on line technological support. √ Promise super product quality with best price and service. √ Support the third part inspection before delivery. √ Ensure the shortest delivery time
Certificate
Specification
Usage Show
Lead Time:
Quantity(Pieces)
1 - 10
11 - 20
21 - 200
>200
Est. Time(days)
3
7
15
To be negotiated
1. Classification The high-voltage cable connects the high-voltage generator and the x-ray tube head in large and medium-sized x-ray machines. The function is to send the high voltage output by the high voltage generator to the two poles of the x-ray tube, and send the heating voltage of the filament to the filament of the x-ray tube. The structure of high-voltage cables: according to the arrangement of the central lines, there are two types of coaxial (concentric) and non-coaxial (non-concentric). 2. Precautions for using high-voltage cables: Prevent excessive bending. Its bending radius should not be less than 5-8 times the diameter of the cable, so as not to cause cracks and reduce the insulation strength. Always keep the cable dry and clean to avoid the erosion of oil, moisture and harmful gases, so as to avoid rubber aging Cable accessories can be ordered separately. When the high voltage cable is used, the bending radius should not less than 66mm.Technical Features
Electrical Data
Rated Voltage
75kVdc
Shield Resistance
0.010 Ohm/m
Coverage Shielding Braid
>95%
Cable Capacity
< 120pF/m
Test Voltages
High Voltage Insulation
90kVdc
Low Voltage Insulation
500 Vac
Mechanical Data: Cable
Outer Diameter
16.5 mm + 0.5
Bending Radius
> 150mm
Low Voltage Conductor
2xl.5mm2
Common Conductor
2x0.75mm2
Conductor Resistance
0.013 Ohm/m
Cable Sheat Colour
Light grey
Mechanical Data: Plug
Multiple Contact Pin
8 point contact
Max. Temperature
110 °C
Flanges
Demountable
Extremely Short Sleeve
34 mm
Small Plug Diameter
40 mm
Solderless Connection
(EMC grounding)
Cable specifications
75/90KV Straight/elbow
75KV CA1-CA11
75/90KV Straight-CA11
picture
Conductor
nominal cross section
1.8mm²
1.8mm²
1.8mm²
Material
Tinned copper
Tinned copper
Tinned copper
Twist
Left
Left
Left
high pressure Insulation
colour
White
White
White
Material
Elastomer
Elastomer
Elastomer
Sheath
colour
grey
grey
grey
Material
PVC
PVC
PVC
thickness
1.5±0.3mm
1.5±0.3mm
1.5±0.3mm
diameter
18.5±0.5mm
14.5±0.5mm
14.5±0.5mm
Main slogan
Cable sheath appearance should be smooth, uniform diameter, with no joint, bubble, bumps and other undesirable phenomena. Weave shield density is not less than 90%. The minimum thickness of the cable insulation and sheath must be 85% more than the nominal thickness. Insulation between the core and the insulated wire, insulation between the core and the ground cable should be able to withstand the AC 1.5KV and keep 10 minutes can not been broken down. Insulation between the core and the shield should be able to withstand the DC 90 KV and keep 15 minutes can not been broken down. The plug body should be able to withstand not less than 1000 times fallen off experiments with no damage. The surface of each plating should be clean and bright. The DC resistance of the conductor and ground cable not more than 11.4 + 5%Ω/m. The insulation resistance of the insulation core wire not less than 1000MΩ•Km. The cable and each part should meet Rohs 3.0 relative requirement. Brass is below 0.1wt. The cable and each part should meet Reach relative requirement.
Packaging & Delivery
Packing for high voltage cable Waterproof carton Packing size: 51cm*50cm*14cm Gross Weight: 12KG; Net Weight: 10KG Portweifang,qingdao,shanghai,beijing Picture Example: